• Models available to meet ICC/ANSI 117.1 low opening force requirements, prefix “PH”.
(For 8-1/2 lbs. of opening force prefix PH andsuffix 8-1/2 lbs.)
• Cold weather fluid option (not available for closers with “DA”)
• Sealed closer option
• Available with floor plate or threshold installation (floor plate shown)
• Cycolac, rustproof cement case
• Standard top pivot: #180 included
• Intermediate pivot(s) recommended for non fire rated opening: 119 (order separately)
• Doors up to 60" (1524mm) to 90" (2286mm) in height should use one intermediate pivot. Each additional 30" (762mm) warrants another intermediate pivot
• For fire rated openings (up to 3 hourassemblies) prefix “F”. This package will besupplied with a steel top pivot (F180) and a non-hold open closer. Intermediate pivot required: FM19,
(order separately).
• Fire rated closers cannot have PH option
• For 20-minute labeled doors suffix “-20” to the part number
• Extended spindles available in 1/2" increments up to 2" longer than standard