ANSI
Meets A156.13 Series 1000, Operational Grade 1.
Federal
Meets FF-H-106C, Series 86 and 87.
UL/ULC Positive Pressure
All locks listed for A Label and lesser class doors, 4" (122cm) x 10"
(305cm) single or 8" (244cm) x 10" (305cm) pair. Letter F and UL
symbol on armored front indicate listing. California State
Reference Code All levers with returns comply; levers return to
within 1/2" (13mm) of door face.
Handing – Handed; field reversible. The lockset can be re-handed
without disassembling the lock case.
Door Thickness
– 1-3/4" (4mm) standard.
Backset
– 2-3/4" (70mm).
Strike
–Wrought brass, bronze or stainless steel. ANSI straight lip
standard.
Lockcase
– Heavy gauge steel, with zinc dichromate finish for
corrosion resistance. 5-7/8" x 4" x 15/16".
Armored Front
– Heavy gauge steel, 8" (203 mm) x 1-1/4"
(32mm) x 3/32" (2mm). Accommodates flat doors and doors
beveled 1/8" (3mm) in 2" (51mm).
Faceplate
–Wrought brass, bronze or stainless steel. Attached by
machine screws to lockcase front.
Latchbolt
– Stainless steel, 2 piece mechanical with anti-friction
insert. 5/8" (16mm) x 1" (25mm) x 3/4" (19mm) throw.
Auxiliary Latchbolt
– 9/16" (14mm) effective throw and 3/8"
(10mm) effective auxiliary latch deadlocking.
Deadbolt
– One-piece stainless steel, 19/32" (15mm) x 1 1/4"
(32mm) x 1" (25mm) throw.
Hub
– Knob: nickel steel, 5/16" (8mm) and 9/32". Lever: nickel
steel, 5/16" (8mm).
Spacing
– Center to center, hub to cylinder: 3-5/8" (92mm).
Center to center, hub to turnpiece 2-7/16" (62 mm).